Use this URL to cite or link to this record in EThOS: https://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.521629
Title: Standards in clinical dual energy X-ray absorptiometry
Author: Steel, Susan A.
ISNI:       0000 0004 2692 747X
Awarding Body: University of Glamorgan
Current Institution: University of South Wales
Date of Award: 2009
Availability of Full Text:
Access from EThOS:
Access from Institution:
Abstract:
Dual Energy X-ray Absorptiometry (DXA) is a digital x-ray technique designed to quantify bone mineral density (BMD), primarily of the lumbar spine and hip, and hence to provide a measure of bone strength and propensity to fracture. The original technology was based on a pencil beam x-ray source but later systems use a fan beam. Additional functionality includes measurement of hand BMD and vertebral fracture assessment (VFA). Smaller devices have also been developed to measure BMD at peripheral sites in the body. As the numerical value of BMD resulting from this technique is used directly in diagnosis and decisions over patient clinical management, it is critical that the measurements are accurate and precise. The work presented in this thesis includes evaluation of the original pencil beam systems, later fan-beam technology, peripheral devices and additional functionality of DXA. This added to the knowledge of the technical capabilities and limitations of the technology providing an indication of precision, factors that may affect accuracy, radiation dose and machine comparison. Novel quality assurance phantoms were designed and constructed for assessing accuracy, precision and long-term stability of DXA-based hand and lateral morphometry techniques. Research was also conducted into factors associated with BMD, treatment compliance and effectiveness and the role of lateral vertebral assessment. This contributes to the growing body of knowledge on clinical risk factors, medical management and the appropriate use of DXA and VFA The thesis also includes the author's contribution to the national training scheme and development of guidelines which have helped raise standards of the technique nationally. These three areas of work contribute to ensuring the safe use of the new and developing technology and appropriate application within the clinical environment supported by highly trained operators and guidelines.
Supervisor: Not available Sponsor: Not available
Qualification Name: Thesis (Ph.D.) Qualification Level: Doctoral
EThOS ID: uk.bl.ethos.521629  DOI: Not available
Keywords: Radiography, Medical ; Digital techniques
Share: