Use this URL to cite or link to this record in EThOS: https://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.393336
Title: An investigation of frequency scanning interferometry for the alignment of the ATLAS semiconductor tracker
Author: Coe, Paul Andrew
ISNI:       0000 0001 3559 7167
Awarding Body: University of Oxford
Current Institution: University of Oxford
Date of Award: 2001
Availability of Full Text:
Access from EThOS:
Full text unavailable from EThOS. Please try the link below.
Access from Institution:
Abstract:
The relative alignment of the silicon detector modules of the ATLAS semiconductor tracker will need remote monitoring during operation, within a high radiation environment. A geodetic grid of distance measurement fibre-coupled interferometers will monitor changes in the shape of the support structure. Eight hundred fibre-coupled grid line interferometers (GLIs) will be compared simultaneously to a stable, evacuated reference interferometer using Frequency Scanning Interferometry (FSI). The GLIs, (from 70 mm to 1400 mm long, with pW level return signals) must be measured to a precision of 1 micron, to reconstruct the grid shape, in three dimensions, to a precision of 10 microns. In this work two important limitations were overcome : 1. Inflated errors due to relative interferometer drift were significantly reduced using two lasers scanned in opposite directions. 2. The fine tuning range was effectively extended by linking the phase information in two 30 GHz fine tuning subscans, separated by a 3.5 THz coarse tuning interval. A demonstration system was built using tunable laser diodes operating at wavelengths close to 836 nm. Several different fibre coupled GLIs were built. Each was measured against an invar reference interferometer sharing the same laboratory air. The 400 mm GLI was measured to a (one standard deviation) precision of 120 nm and a 1195 mm GLI to a precision of 215 nm. Decreasing the GLI signal was not found to significantly degrade the measurement precision. Spurious reflections and vibrations were separately introduced to degrade the measurements. The errors were found to increase, with errors larger than 4 parts per million, observed for vibrations of 400 nm peak to peak amplitude. Suggestions are given for reducing remaining errors. Further investigations into the effects of vibrations and spurious reflections are recommended.
Supervisor: Howell, David Sponsor: Point Source Ltd ; Particle Physics and Astronomy Research Council
Qualification Name: Thesis (Ph.D.) Qualification Level: Doctoral
EThOS ID: uk.bl.ethos.393336  DOI: Not available
Keywords: Length measurement ; Position sensitive particle detectors ; Optics ; Interferometry ; Laser interferometers
Share: