Use this URL to cite or link to this record in EThOS: http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.720485
Title: Edge loading effect on total hip replacement
Author: Torabi Kachousangi, Ehsanollah
Awarding Body: University of Warwick
Current Institution: University of Warwick
Date of Award: 2016
Availability of Full Text:
Access from EThOS:
Full text unavailable from EThOS. Thesis embargoed until 03 Apr 2019
Access from Institution:
Abstract:
The most important hip post-surgery problem is named Edge Loading (EL). This phenomenon significantly increases the contact pressure on the ball and the socket of the hip prosthesis hence decreasing the lifetime of the hip prosthesis drastically. Nowadays millions of patients cannot go under total hip replacement surgery due to the short lifetime of the hip prostheses. This research mainly focuses on finding solution for reducing the effect of this phenomenon. In this research, reasons of EL are investigated and important factors in designing of the prosthesis are studied. Furthermore, a novel hip prosthesis is proposed. The model has been successfully patented with PCT number: PCT/GB2015/052933 and published with International Publication Number: “WO2016/055783Al”. In this study the proposed design is analysed using three methods and the results are compared with the best available hip prosthesis in the market. The key results of the proposed design are outlined below: -Comparison of the features of the proposed design with those of the available hip prosthesis suggests a promising outcome. This is mostly due to eliminating of the EL causes, in the new design. -According to Hertzian Contact Theory, the proposed design reduces contact pressure during EL by 99.7% in comparison with the best available prosthesis in the market. This represents an upper limit. -Finite element method simulation demonstrates up to 63% reduction (lower limit) of contact pressure during EL and also Neck-Rim/Ring impingement by the proposed design in comparison with the best available prosthesis in the market. Although reduction of contact pressure by the novel design is noticeable, aforementioned methods show different results. This is due to the limitation of every method in this study. In this regard the novel design expecting to reduce contact pressure during EL / Microseparation more than 63% but less than 99.7%. The novel design may open a new path for the total hip replacement surgery, and solve the EL problem forever.
Supervisor: Not available Sponsor: Not available
Qualification Name: Thesis (Ph.D.) Qualification Level: Doctoral
EThOS ID: uk.bl.ethos.720485  DOI: Not available
Keywords: RD Surgery ; TA Engineering (General). Civil engineering (General)