Title: Design and operation of a wide gap streamer chamber
Author: Mishra, Seeta Ram
Awarding Body: University of London
Current Institution: Royal Holloway, University of London
Date of Award: 1969
Availability of Full Text:
Access from EThOS:
Access from Institution:
Abstract:
A wide gap streamer chamber has been designed and constructed. Its performance in various modes has been investigated. It is shown that an angular accuracy of 1.5 m rad can be achieved for a 20 centimetre track. The chamber has been applied to the study of multiple scattering of 100 Mev muons in one inch of lead. A large departure from theory has been observed, and the analysis has indicated a second narrow component of the distribution of the particles plotted against the projected angles of scattering. The chamber has been modified to study low energy particles.
Supervisor: Not available Sponsor: Not available
Qualification Name: Thesis (Ph.D.) Qualification Level: Doctoral
EThOS ID: uk.bl.ethos.704058  DOI: Not available
Keywords: High Energy Physics