Title: Control of asymmetric permanent magnet synchronous generator systems
Author: Hu, Yashan
ISNI:       0000 0004 5918 6727
Awarding Body: University of Sheffield
Current Institution: University of Sheffield
Date of Award: 2016
Availability of Full Text:
Access through EThOS:
Full text unavailable from EThOS. Thesis embargoed until 01 May 2020
Access through Institution:
Abstract:
The thesis focuses on the control of asymmetric permanent magnet synchronous generator (PMSG) system, with particular reference to the suppression of its second harmonic (2h) power, DC bus voltage and torque ripples. The asymmetries include the unbalanced resistances, unbalanced inductances, and unbalanced 3-phase back-electromotive forces (EMFs). The mathematical model of the general asymmetries in the PMSG system is firstly presented. The power ripple and torque ripple due to the asymmetries without/with negative-(N-) sequence currents are then analysed in detail. It shows that there are 2h impedances in the synchronous dq-axis frame. Consequently, the N-sequence currents emerge under the conventional current proportional and integral (PI) control, which will result in undesired 2h power, DC bus voltage and torque ripples. To suppress the 2h torque resulted from the N-sequence currents, three typical methods aiming for balanced currents without N-sequence currents are reviewed, evaluated and their relationship is revealed. It shows that all these three methods are capable of suppressing the N-sequence currents as verified by experiments. However, the 2h power and DC bus voltage cannot be suppressed. To suppress the undesired 2h power and DC bus voltage, an improved power control without any sequential component decomposers under general unbalanced conditions is proposed. Its effectiveness is validated by elaborated experiments on a prototype PMSG with inherent asymmetry and deliberately introduced asymmetries. However, the 2h torque is compromised. To solve the 2h torque, power and DC bus voltage simultaneously, the compensation in parallel with the DC bus is investigated in the PMSG system with asymmetric impedances. The undesired 2h power from the PMSG is compensated by the 2h power from the compensation unit. Two topologies of the compensation unit and corresponding control methods are investigated, while the compensation effectiveness is validated by experiments. Furthermore, the compensation unit with external circuits in series with the asymmetric PMSG is investigated. By the compensation in series, the original unbalanced system is modified to a balanced system in theory. Therefore, the N-sequence currents, 2h power, DC bus voltage, and torque ripple can be naturally suppressed. The feasibility of this compensation method is verified by experiments at different speeds and load conditions, although the effectiveness may be slightly affected by the non-linearity of the compensation inductors in practice. Finally, the research of suppressing the 2h DC bus voltage and torque ripple is extended to the dual 3-phase PMSG system with one channel failed. By utilizing the windings, rectifier or inverter in the faulty channel which are still functional, three methods designated as two sets in parallel, two DC buses in parallel and N-sequence currents compensation are investigated, which require minimum extra hardware investment compared with the compensation in parallel and in series.
Supervisor: Zhu, Z. Q. ; Odavic, Milijana Sponsor: Not available
Qualification Name: Thesis (Ph.D.) Qualification Level: Doctoral
EThOS ID: uk.bl.ethos.689309  DOI: Not available
Share: