Use this URL to cite or link to this record in EThOS: http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.677111
Title: Motion gating for X-ray guided interventional electrophysiology procedures
Author: Panayiotou, Maria
ISNI:       0000 0004 5368 3271
Awarding Body: King's College London
Current Institution: King's College London (University of London)
Date of Award: 2015
Availability of Full Text:
Access from EThOS:
Access from Institution:
Abstract:
Atrial fibrillation (AF) is a common supraventricular arrhythmia, characterized by irregular and uncoordinated contraction of the atrium. Although AF itself is not lethal, it accounts for secondary diseases and morbidity and mortality. The minimally-invasive radiofrequency ablation (RFA) procedure is a commonly performed treatment option for AF, guided by Xray fluoroscopy. While it provides high temporal and spatial resolution, X-ray fluoroscopy has poor soft-tissue contrast. In order to enhance image guidance, volumetric roadmaps overlaid on live X-ray fluoroscopy may be used. However, these roadmaps are often static and do not reflect cardiorespiratorymotion. Real-time roadmap update is important to compensate for this motion and maintain the accuracy of the guidance information, thereby allowing accurate determination of catheter-based ablation treatment sites. Motion gating is crucial for achieving this accuracy. Four novel and clinically applicable robust-to-noise motion gating techniques are developed and presented in this thesis. The first proposed technique, Tracked-principal component analysis (PCA), is based on the formation of a novel statistical model of the motion of a coronary sinus (CS) catheter using PCA of tracked electrode locations from monoplane X-ray fluoroscopy images. Motion gating was later further extended to be applicable to more types of minimally invasive procedures, such as Cardiac resynchronisation therapy, where the CS catheter is not present in the X-ray images. This is achieved by the development of two robust to varying image-content techniques, the hierarchical manifold learning based and the Masked-PCA techniques. To avoid the limitation of the requirement to build a separate model for each X-ray view, an X-ray system View-angle independent technique was developed based on learning CS catheter motion using PCA and then applying the derived motion model to unseen images taken at arbitrary projections. Applications of the motion gating techniques spanning from basic research to clinical tasks are demonstrated. These include catheter reconstruction in 3D from catheter tracking in gated sequential biplane X-ray images that can effectively achieve 2D/3D registration of 3D cardiac data (CT or MRI) to X-ray fluoroscopy; motion gating of 3D rotational X-ray angiography sequences where the angulation of the scanner is changed between frames; and motion compensation on unseen images taken at any arbitrary projection, by integrating cardiorespiratory motion into MRI-derived roadmaps fused with live X-ray fluoroscopy. This thesis is devoted to the development of robust-to-noise motion gating techniques and their use for improved procedure guidance while at the same time minimising patient and staff exposure to radiation, by allowing the use of lower-dose fluoroscopy. Results indicate that, within the constraints of acceptable accuracy, the achievable dose reduction factor is 1/25 for the HML-based and Masked-PCA techniques, indicating a dose reduction of more than 25 times, between 1/10 and 1/25 for the Tracked-PCA technique and around 1/10 for the View-angle independent technique.
Supervisor: Rhode, Kawaldeep Singh ; King, Andrew Peter Sponsor: Not available
Qualification Name: Thesis (Ph.D.) Qualification Level: Doctoral
EThOS ID: uk.bl.ethos.677111  DOI: Not available
Share: