Use this URL to cite or link to this record in EThOS: http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.649447
Title: Influences of stimulus characteristics and ocular surface conditions on non-invasive corneal sensitivity measurement
Author: Nosch, Daniela
ISNI:       0000 0004 4692 2369
Awarding Body: Cardiff University
Current Institution: Cardiff University
Date of Award: 2015
Availability of Full Text:
Access through EThOS:
Access through Institution:
Abstract:
Purpose: To i) investigate the stimulus characteristics of the Belmonte OPM pneumatic aesthesiometer in vitro and in vivo; ii) explore the relationship between corneal sensitivity threshold (CST), spontaneous eye blink rate (SEBR), ocular surface temperature (OST) and tear film quality, using the non-contact aesthesiometer (NCCA), and iii) investigate the relationship between heating and cooling of the ocular surface on CST (with the NCCA). Methods: Stimulus flow rate (airflow meter), air stimulus volume (air capture) and force (weight scales) were recorded in vitro. Stimulus temperature was measured in vitro (using thermocouples) and in vivo (via a thermal infrared camera). SEBR, CST, OST, NIBUT and lipid pattern of the tear film were recorded. CST (using NCCA), OST and tear film quality were obtained at baseline, and after increasing and decreasing OST, using heated goggles or cooling gel mask, respectively, until OST baseline level was reached again. OST was recorded during stimulus presentation at CST, immediately after heating and cooling of the ocular surface. Conclusions: Stimulus characteristics measured in vitro showed little variability and may therefore be considered as reliable. Stimulus temperature recorded in vivo showed that a change in stimulus flow rate produced a small, but statistically significant effect on OST. Consequently, this air stimulus may not be exclusively ‘mechanical’, and may provoke an additional response from temperature sensitive C fibres. A moderate correlation between corneal sensitivity and blink frequency was established, and a strong correlation between tear film quality, SEBR and OST was obtained, emphasising that ocular surface condition represents one important trigger for the initiation of a blink. After both an increase and a decrease of OST, a greater localised OST decrease was required at CST, indicating that heating or cooling of the ocular surface may affect the nervous activity / sensitivity of cold thermoreceptors in the superficial cornea.
Supervisor: Not available Sponsor: Not available
Qualification Name: Thesis (Ph.D.) Qualification Level: Doctoral
EThOS ID: uk.bl.ethos.649447  DOI: Not available
Keywords: RE Ophthalmology
Share: