Use this URL to cite or link to this record in EThOS: http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.626328
Title: Development of preparative microfluidic techniques for lysis of microbial cells and affinity purification of proteins
Author: El-Sabbahy, H.
Awarding Body: University College London (University of London)
Current Institution: University College London (University of London)
Date of Award: 2013
Availability of Full Text:
Access from EThOS:
Full text unavailable from EThOS. Please try the link below.
Access from Institution:
Abstract:
In order to fully realise the benefits of microscale mammalian cell culture and microbial fermentation systems, a device capable of online sample preparation to enable further investigation of product quality is a key requirement. The aim of this work is to move toward such a device by designing and characterising a microfluidic lysis device and microaffinity chromatography device that are compatible with each other. The resulting microfluidic lysis device is useful for preparatory lysis of microbial cells. It works by mixing a lysis reagent (BugBuster MastermixTM), with microbial culture, using a T-Piece connection. Lysis takes place in a 700µm internal diameter fused silica capillary. The device was able to successfully lyse microbial cells with similar active Glutathione S Transferase release to sonication. The operating flowrate range of the device was 3.207µL min-1 to 6.414 µL min-1 and the device volume was 30µL - 60µL. The microaffinity chromatography column performed well in studies with pure Glutathione S Transferase. It showed good loading and elution behaviour. The breakthrough and elution curves, and quantity of protein eluted per unit bed volume, were similar to lab scale. The difference being as a result of experimental error. The column also performed well with a 100% clarified Escherichia coli lysate containing recombinant Glutathione S Transferase from Schistosoma japonicum. The eluate had a purity of 55% and concentration of 2.24 mg/ml. The column was fabricated from inexpensive fused silica capillary. It had an internal diameter of 700µm, a length of 5cm (the same length as a typical lab scale Glutathione Affinity column), and a bed volume of approximately 19µL. The operating flowrate range for the column was the same as the microlysis device.
Supervisor: Not available Sponsor: Not available
Qualification Name: Thesis (Ph.D.) Qualification Level: Doctoral
EThOS ID: uk.bl.ethos.626328  DOI: Not available
Share: