Use this URL to cite or link to this record in EThOS: http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.493672
Title: An investigation into physiological parameter quantification using arterial spin labelling
Author: Carr, John Patrick
Awarding Body: Manchester University
Current Institution: University of Manchester
Date of Award: 2007
Availability of Full Text:
Access from EThOS:
Abstract:
MRI offers a non invasive method of quantifying physiological parameters related to the such as perfusion (F), blood volume (vf,) and capillary permeability surface area product {PS) in vivo. Changes in such parameters are present in a wide range of diseases ranging from psychological disorders to cancer. Quantification of such parameters is therefore of major benefit in both the diagnosis and understanding of such disease as well as for assessment of potential therapies.
Supervisor: Not available Sponsor: Not available
Qualification Name: Thesis (Ph.D.) Qualification Level: Doctoral
EThOS ID: uk.bl.ethos.493672  DOI: Not available