Title: High sensitivity electrical capacitance tomography system and its application
Author: Chondronasios, Athanasios
ISNI:       0000 0001 3547 0481
Awarding Body: University of Manchester
Current Institution: University of Manchester
Date of Award: 2003
Availability of Full Text:
Access through EThOS:
Abstract:
The potential of Electrical Capacitance Tomography (ECT) to quantify low concentration multiphase processes has been investigated. While some simple distributions in areas such as pneumatic conveying have been reported previously, imaging low concentrations gives a number of additional challenges. The research described here examines the performance limits of capacitance tomography in the areas of information utilisation, low concentration imaging and soft-field error effects.
Supervisor: Not available Sponsor: Not available
Qualification Name: Thesis (Ph.D.) Qualification Level: Doctoral